Use room size and relevant conditions to estimate an initial heating or cooling capacity. Actual equipment sizing also depends on insulation, windows, climate and a professional load calculation.
Describe the room to estimate the cooling or heating capacity it needs.
Heat loss or gain through the walls and ceiling for a given temperature difference between inside and outside.
A BTU, or British thermal unit, is a measure of heat. One BTU is about the heat needed to warm one pound of water by one degree Fahrenheit. Air conditioners and heaters are rated in BTU per hour, which says how much heat they can move in an hour. One BTU per hour is about 0.293 watt, and 12,000 BTU per hour is called one ton of cooling.
The page has two estimators. The room estimate works from the floor area, ceiling height, number of people, type of room, insulation, sun and climate. The whole-house estimate adds up the wall and ceiling surface and multiplies by the temperature difference and an insulation factor. Each shows the answer in BTU per hour, in watts and in tons.
The room tool opens on a 200 square foot bedroom with an 8 foot ceiling, 2 people, and average insulation, sun and climate. The estimate is 20 BTU per hour for every square foot plus a base of 2,500: 20 × 200 + 2,500 = 6,500 BTU per hour. That is 1,905 watts, or 0.54 tons. Ceilings of 8 feet or less add nothing, two people add nothing, and the average settings multiply by 1.
| Factor | Setting | Effect |
|---|---|---|
| Insulation | Good / Average / Poor | × 0.8 / 1 / 1.2 |
| Sun exposure | Heavily shaded / Average / Very sunny | × 0.9 / 1 / 1.1 |
| Climate | Cold / Average / Hot | × 0.85 / 1 / 1.2 |
| People | Each person beyond the first two | + 600 BTU per hour |
| Kitchen | Type of room | + 4,000 BTU per hour |
| Living room | Type of room | + 1,000 BTU per hour |
| Second floor or above | Type of room | × 1.1, because heat rises |
| Insulation | BTU per hour for the 200 sq ft bedroom |
|---|---|
| Good | 5,200 |
| Average | 6,500 |
| Poor | 7,800 |
A 300 square foot living room with a 9 foot ceiling and 4 people, very sunny and in a hot climate. The base is 20 × 300 + 2,500 = 8,500, and the taller ceiling adds 1,000, making 9,500. The sun (× 1.1) and the hot climate (× 1.2) take it to 12,540. The two extra people add 1,200 and the living room adds 1,000, for 14,740 BTU per hour, about 4,320 watts. A 150 square foot kitchen with an 8 foot ceiling, in contrast, comes to (3,000 + 2,500) + 4,000 = 9,500.
Ceilings above 8 feet add extra load. Up to 10 feet it adds 1,000 BTU per hour for each extra foot. Above 10 feet the add-on is steeper, and in larger rooms it is scaled up as well (by up to 3 times at very large areas). The table shows the add-on in BTU per hour.
| Room size (sq ft) | 9 ft ceiling | 10 ft ceiling | 12 ft ceiling |
|---|---|---|---|
| 200 | 1,000 | 2,000 | 3,467 |
| 500 | 1,000 | 2,000 | 3,467 |
| 1,000 | 2,000 | 4,000 | 6,933 |
| 2,000 | 2,500 | 5,000 | 8,667 |
You can enter the room in square metres and the ceiling in metres. A 20 square metre room with a 2.5 metre ceiling is 215.3 square feet with an 8.2 foot ceiling, which gives 7,008 BTU per hour.
ENERGY STAR’s room air conditioner guide gives capacity by room area, and applies the same kind of adjustments for shade, sun, people and a kitchen. The calculator’s base is a little higher, so its answer sits above the chart, as the table shows. Round up to the nearest size sold.
| Room area (sq ft) | Calculator (8 ft ceiling) | ENERGY STAR chart | Calculator vs chart |
|---|---|---|---|
| 300 | 8,500 | 7,000 | +21% |
| 400 | 10,500 | 9,000 | +17% |
| 500 | 12,500 | 12,000 | +4% |
| 600 | 14,500 | 14,000 | +4% |
| 1,000 | 22,500 | 18,000 | +25% |
The house tool opens on a house 20 feet wide and 15 feet long with an 8 foot ceiling, a 45°F temperature difference and average insulation. The surface is the floor or ceiling area (20 × 15 = 300) plus the four walls (2 × (20 + 15) × 8 = 560), which is 860 square feet. The load is the temperature difference times the insulation factor times the surface: 45 × 0.40 × 860 = 15,480 BTU per hour, which is 4,537 watts or 1.29 tons. Use the difference between the hottest or coldest day and the temperature you want inside. If you enter the difference in °C, the tool multiplies it by 1.8.
| Temperature difference (°F) | Good (0.24) | Average (0.40) | Poor (0.84) |
|---|---|---|---|
| 30 | 6,192 | 10,320 | 21,672 |
| 45 | 9,288 | 15,480 | 32,508 |
| 60 | 12,384 | 20,640 | 43,344 |
A unit that is too small runs all day and never catches up. A unit that is too large switches on and off too often, which wastes power and removes less moisture, leaving the room cool but damp. Round the estimate up to the nearest size sold, and for a whole house have an installer carry out a full load calculation, since windows, doors and air leaks matter a great deal.
An air conditioner’s efficiency is given as EER, the BTU per hour divided by the watts it draws. The default 6,500 BTU per hour unit at an EER of 10 draws about 650 W, which is 5.2 kWh over an 8-hour day of continuous running. At an EER of 12 it draws about 542 W. Use the Electricity Calculator with your own rate to turn that into a cost.
The large number is the capacity in BTU per hour, with the same figure in watts and, for the house method, in tons. Treat it as a starting point, then round up to a size that is sold.
A common rule of thumb is about 20 BTU per hour for each square foot of floor space. This calculator adds a base of 2,500 and adjustments for the ceiling, insulation, sun, climate, people and the type of room.
One ton of cooling is 12,000 BTU per hour, which is about 3,517 watts.
It cools the room quickly and switches off before it has removed much moisture, so the room can feel cool but damp. It also cycles on and off, which wastes power.
It adds up the wall and ceiling surface, then multiplies by the temperature difference and a factor for insulation: 0.24 for good, 0.40 for average and 0.84 for poor. A 20 by 15 foot house with 8 foot ceilings and a 45 degree difference comes to 15,480 BTU per hour.
Use the room method for one room, such as a bedroom or kitchen. Use the house method for a whole house, and ask an installer for a full load calculation before buying central equipment.
The calculator adds 4,000 BTU per hour for a kitchen because cooking produces a lot of heat. A living room adds 1,000.
Sources: ENERGY STAR (archived): Room air conditioner sizing; Wikipedia: British thermal unit; Wikipedia: Ton of refrigeration